Summary:

  • Ongoing long term water intrusion at exterior wall 
  • Dis-assembled exterior wall and window system
  • Applied waterproof membrane system to wall
  • Waterproofed all penetrations and openings 
  • Installed new window head and sill flashings
  • Applied radiant barrier within wall system
  • Re-assembled exterior wall and window systems